Nearly 375 million people worldwide live with knee osteoarthritis¹, one of the leading causes of disability in older adults. Precise measurements of leg alignment and leg length are important for diagnosis, surgical planning and post-operative assessment. Yet current imaging workflows are time-consuming and subject to reader variability. Full-leg radiographs are the clinical standard for measuring leg alignment but they often require taking multiple images and stitched them together. Even slight rotation of the leg during imaging can affect measurement accuracy and may require repeat X-rays.
IB Lab Lama analyzes full-leg radiographs in under 20 seconds2* and delivers 16 features from long-leg, knee and lateral knee radiographs. It streamlines clinical workflows by predicting the leg axis directly from AP knee X-rays — giving an alternative to tedious full-leg imaging — while automatically detecting and correcting for patient rotation** to support accurate planning and documentation.
On 3 different view positions.
IB Lab Lama 3.0 predicts leg axis parameters directly from an AP knee X-ray — giving an alternative to long-leg radiographs. This reduces acquisition time, potential stitching errors and lowers the imaging burden without compromising clinical information.
IB Lab Lama 3.0 detects and corrects for patient rotation during image acquisition and provides corrected values within an additional report.**
Reading time with AI on long-leg radiographs vs. ~135 sec manual2*
Faster than manual measurement2*
Peer-reviewed publications3
Leg Length Assessment
Leg Alignment Assessment
.png)
.png)
IB Lab LAMA is a fully-automated AI-driven software device for processing full leg anteroposterior (AP) radiographs and anteroposterior (AP) and lateral (LAT) radiographs of the knee. It is designed to leverage deep-learning-based algorithms to detect anatomical features in order to aid users in the assessment of leg length discrepancy, quantitative lower limb alignment and knee stability parameters. It should not be used in-lieu of full patient evaluation or solely relied upon to make or confirm a diagnosis. All AI-generated measurements and morphological insights must be reviewed by a healthcare professional trained in radiology. IB Lab Lama is intended to be used by healthcare professionals trained in radiology. IB Lab Lama is intended to be used on patients of 8+ years (Full Leg AP radiographs) or 18+ years (AP and LAT Knee radiographs).
IB Lab Lama automatically measures leg length and leg alignment on X-rays:
Alignment parameters are also provided rotation-corrected.
AP full-leg (long-leg) radiographs, and AP and lateral short-film knee radiographs.
Yes. IB Lab Lama derives the key leg axis parameters (HKA, AMA, mLDFA, mMPTA) directly from a standard AP short-film knee radiograph (Chen et al. 2024). This makes it an alternative to time-consuming long-leg imaging, with less acquisition effort and no stitching errors.
Studies show very high agreement with manual measurements by experienced physicians, with a mean deviation of 0.5° or less (Stotter et al. 2023). Repeated measurements on the same image always deliver the same result, which ensures standardized, user-independent assessments (Simon et al. 2021, Archer et al. 2024).
Several studies show substantial time savings compared to manual measurement:
Some studies used earlier versions of IB Lab Lama, as we continuously develop the product. How quickly results are available in your practice also depends on your PACS and its settings.
Patients aged 8 and older for full-leg radiographs, and 18 and older for knee radiographs, with suspected or diagnosed leg malalignment or leg length discrepancy.
Before surgery, IB Lab Lama analyzes the parameters relevant for knee procedures: leg axis, joint angles, CPAK phenotype and tibial slope, standardized and also rotation-corrected. IB Lab Lama does not offer templating. After total knee arthroplasty, it measures prosthesis alignment, supporting post-operative assessment and documentation.
Yes. IB Lab Lama measures reliably after total knee arthroplasty (Schwarz et al. 2022, Russell et al. 2024) and after corrective osteotomy (Stotter et al. 2023, Mitterer et al. 2023). Rotation correction is currently available only for radiographs without a knee implant.
IB Lab Lama creates a report with all measurements and the measurement lines drawn on the image. It appears directly in your PACS alongside the original radiograph.
No. IB Lab Lama runs fully automatically in the background. There is no extra software to open and no landmarks to set. All that remains is your clinical review of the results.
Yes. IB Lab Lama integrates with common PACS systems.
IB Lab Lama is installed on-premise at your practice or hospital. Image data never leaves your site.
Yes. IB Lab Lama is a Class IIa medical device under the MDR, certified by TÜV SÜD (Notified Body 0123).
* Measured with IB Lab Lama 1.04, a previous version of IB Lab Lama 3.0.
** Post-operative rotation correction is currently under development and subject to completion of conformity assessment under the MDR. For the current status, contact IB Lab GmbH or refer to the latest labeling documents in the customer portal at https://support.imagebiopsy.com.